<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>2</title>
<title_fa>1</title_fa>
<short_title>3</short_title>
<subject>Literature &amp; Humanities</subject>
<web_url>http://ijwph.daneshafarand.org</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>9</journal_id_issn>
<journal_id_issn_online>10</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1389</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2010</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>2</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مطالعه و مقایسه ماکزیمم فشار اعمالی در مفصل غضروفی رادیواسکافوئید با توجه به دو روش المان محدود (FEM) و مدل صلب- فنریت (RBSM)</title_fa>
	<title>Investigation and comparing peak contact pressure on the Radio-Scaphoid joint with RBSM &amp; FEM methods</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa></content_type_fa>
	<content_type></content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&lt;strong&gt; مقدمه: &lt;/strong&gt;مطالعه سینتیک مچ نقش به خصوصی در گسترش آسیب&#8204;شناسی دارد و محققین در جستجوی یافتن درمان&#8204;های جدید، کاهش درد و برگرداندن عملکرد مناسب مچ می&#8204;باشند.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&lt;strong&gt; هدف: &lt;/strong&gt;هدف از این مقاله، بررسی و مقایسه ماکزیمم فشار اعمالی در طول سطوح تماسی مفصل غضروفی رادیواسکافوئید توسط دو روش المان محدود و مدل صلب-فنریت محاسباتی می&#8204;باشد.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&amp;nbsp;&lt;strong&gt; مواد و روش&#8204;ها:&lt;/strong&gt;در مدل صلب- فنریت محاسباتی، ساختار مچ از اجسام صلب که نقش استخوان، فنرهای کششی و فشاری که به ترتیب نقش لیگامان&amp;shy;ها و غضروف&amp;shy;ها را بازی می&#8204;کنند، تشکیل شده است و دارای یک سری روابط ریاضیاتی است که تنش و کرنش ایجاد شده نسبت به بار اعمالی را در ناحیه مفصل رادیواسکافوئید محاسبه می&#8204;کند.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;یافته&#8204;ها: &lt;/strong&gt;نتایجی&amp;nbsp;که از این دو روش به دست می&amp;shy;آید حاکی از آن است که ماکزیمم فشار اعمالی در سطح تماسی مورد نظر تقریباً یکسان می&#8204;باشد. اما روش صلب- فنریت نسبت به روش المان محدود دارای روابط ساده&amp;shy;تر و موثرتر در پیش بینی توزیع فشار تماسی در طی بارگذاری&amp;shy;های متقارن و نامتقارن می&#8204;باشد. خصوصاً بازده محاسباتی روش صلب- فنریت برای بررسی توزیع فشار مفاصل در کاربردهای ارتوپدیک قابل توجه می&#8204;باشد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;Study of the wrist kinetics is important role in progressive of pathology and researches hope to develop new therapies for reduce the pains and restore the functional ability in the wrist joint. The aim of this study is investigating and comparing the peak contact pressure in radio-scaphoid articular joint with regard to finite element method &amp; Rigid Body Spring Model method. With RBSM technique the structure of the wrist is represented in a model as a collection of rigid bodies, representing the bones, interconnected by compressive and tensile spring elements, representing cartilage and ligaments. This Method includes mathematical formula that calculated the stress &amp; strain in regard to impact load in the Radio-Scaphoid joint. Results for joint model indicate that these two methods predict similar peak contact pressure on joint surface. But the RBSM is relatively simple and effective in predicting joint contact pressure under symmetric and non-symmetric loading. The computational efficiency of the RBSM method is particularly attractive for pre-operative planning of reconstructive surgical procedures in orthopedics.&lt;/p&gt;
</abstract>
	<keyword_fa>فشار تماسی, مفصل رادیواسکافوئید, مدل صلب فنریت,  مدل مفصلی</keyword_fa>
	<keyword>Contact pressure, Radio-Scaphoid joint, RBSM, joint model</keyword>
	<start_page>18</start_page>
	<end_page>23</end_page>
	<web_url>http://ijwph.daneshafarand.org/browse.php?a_code=A-10-115-2&amp;slc_lang=fa&amp;sid=3</web_url>


<author_list>
	<author>
	<first_name>A.</first_name>
	<middle_name></middle_name>
	<last_name>Javanmardian</last_name>
	<suffix></suffix>
	<first_name_fa>آرین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جوانمردیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>aryan_javanmardian@yahoo.com</email>
	<code>1003194753284600375165</code>
	<orcid>1003194753284600375165</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Haghpanahi</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حق پناهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mhaghpanahi@yahoo.com</email>
	<code>1003194753284600375164</code>
	<orcid>1003194753284600375164</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
