<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>2</title>
<title_fa>1</title_fa>
<short_title>3</short_title>
<subject>Literature &amp; Humanities</subject>
<web_url>http://ijwph.daneshafarand.org</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>9</journal_id_issn>
<journal_id_issn_online>10</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1387</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2009</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>1</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ولیدسازی دستگاه ثبت مدت زمان استفاده از ارتز</title_fa>
	<title>Validation of a Device for Registering Orthotic Wearing Time during the Laboratory Climate Tests on Normal Volunteers</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa></content_type_fa>
	<content_type></content_type>
	<abstract_fa>&lt;p&gt;هدف از انجام این مطالعه ارزیابی روایی و پایایی دستگاه ثبت مدت زمان استفاده از ارتز ساخت ایران با استفاده از ارتز&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;&lt;span en-gb=&quot;&quot; fa=&quot;&quot; mso-ansi-language:=&quot;&quot; mso-bidi-language:=&quot;&quot; mso-fareast-font-family:=&quot;&quot; mso-fareast-language:=&quot;&quot; new=&quot;&quot; times=&quot;&quot;&gt;CASH&lt;/span&gt;&lt;/span&gt;&amp;nbsp;به منظور کاربردی ساختن آن به عنوان ابزاری برای مطالعات و تحقیقات ارتوپدی فنی، مهندسی پزشکی و رشته&amp;shy;های مرتبط بود. جمع&amp;shy;آوری داده&#8204;های زمانی به صورت همزمان توسط آزمونگر و دستگاه ثبت مدت زمان استفاده ازز ارتزانجام می&amp;shy;گرفت. آزمونگر در هنگام انجام آزمون&amp;shy;ها داده&amp;shy;های زمانی را بر مبنای ساعت دیجیتال و کرونومتر در فرم ثبت اطلاعات زمانی یادداشت می&amp;shy;کرد. پس از اتمام هر آزمایش داده&amp;shy;های ذخیره شده در بریس تایمر به رایانه انتقال داده می&amp;shy;شدند و در کنار اطلاعات کرونومتر ثبت می&amp;shy;شدند&lt;span en-us=&quot;&quot; fa=&quot;&quot; garamond=&quot;&quot; mso-ansi-language:=&quot;&quot; mso-ascii-font-family:=&quot;&quot; mso-bidi-language:=&quot;&quot; mso-fareast-font-family:=&quot;&quot; mso-fareast-language:=&quot;&quot; mso-hansi-font-family:=&quot;&quot; new=&quot;&quot; times=&quot;&quot;&gt;.&lt;/span&gt;&amp;nbsp;به منظور تعیین پایایی دستگاه آزمون&amp;shy;ها توسط 5 آزمونگر مختلف تکرار شدند. برای تعیین روایی و پایایی دستگاه ثبت مدت زمان استفاده از ارتزاز آنالیز پایایی مقیاس و آزمون همبستگی مابین مدت زمان استفاده از ارتز که توسط بریس تایمر ثبت شده و مدت زمان ثبت شده بر اساس ساعت دیجیتال استفاده شد. همچنین از آزمون&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;&lt;span en-us=&quot;&quot; fa=&quot;&quot; mso-ansi-language:=&quot;&quot; mso-bidi-language:=&quot;&quot; mso-fareast-font-family:=&quot;&quot; mso-fareast-language:=&quot;&quot; new=&quot;&quot; times=&quot;&quot;&gt;t&lt;/span&gt;&amp;nbsp;یک نمونه برای مقایسه میانگین&amp;shy;های این دو گروه استفاده شد. نتیجه اینکه&lt;/span&gt;&amp;nbsp;&amp;nbsp;&lt;span en-gb=&quot;&quot; fa=&quot;&quot; mso-ansi-language:=&quot;&quot; mso-bidi-language:=&quot;&quot; mso-fareast-font-family:=&quot;&quot; mso-fareast-language:=&quot;&quot; new=&quot;&quot; times=&quot;&quot;&gt;دستگاه ثبت مدت زمان استفاده از ارتزبه طور میانگین در هر آزمون نوبت استفاده از ارتز را یکی بیشتر از کرونومتر ثبت کرده بود. این اختلاف 1 موردی در هر آزمون(به طور میانگین) به دلیل قطع و وصل شدن سنسور ناشی از حرکات ناخواسته و شدید فرد در داخل ارتز و بنابراین برداشته شدن نیرو از سطح سنسور و قرار گرفتن سنسور در حالت خاموش می&amp;shy;باشد. در همه آزمون&amp;shy;ها خطای میانگین کمتر از یک دقیقه و انحراف معیار میانگین برابر با 1 دقیقه بود. بنابراین می&amp;shy;توان گفت که اولین&lt;/span&gt;&amp;nbsp;&lt;span en-us=&quot;&quot; fa=&quot;&quot; mso-ansi-language:=&quot;&quot; mso-bidi-language:=&quot;&quot; mso-fareast-font-family:=&quot;&quot; mso-fareast-language:=&quot;&quot; new=&quot;&quot; times=&quot;&quot;&gt;بریس تایمر ایرانی دقتی در حد ثانیه دارد و روایی و پایایی برای استفاده به عنوان ابزار تحقیقات در مطالعات ارتوپدی فنی و سایر رشته&amp;shy;های مربوطه را دارا می&amp;shy;باشد.&lt;/span&gt;&lt;span dir=&quot;rtl&quot; en-us=&quot;&quot; fa=&quot;&quot; lang=&quot;FA&quot; mso-ansi-language:=&quot;&quot; mso-bidi-language:=&quot;&quot; mso-fareast-font-family:=&quot;&quot; mso-fareast-language:=&quot;&quot; new=&quot;&quot; style=&quot;FONT-SIZE: 12pt FONT-FAMILY: &quot; times=&quot;&quot;&gt; &lt;/span&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p class=&quot;abstract&quot; style=&quot;TEXT-JUSTIFY: distribute-all-lines MARGIN: auto 0cm auto 36pt TEXT-ALIGN: justify&quot;&gt;&lt;font face=&quot;Times New Roman&quot; size=&quot;3&quot;&gt;Laboratory instrumentation of orthoses and prostheses can be used to objectively gain accurate information. In this study the measurement of orthosis wearing time during laboratory climate tests with normal volunteers were accomplished to determine the validity and reliability of the device for registering orthotic wearing time that was designed and fabricated in &lt;country-region w:st=&quot;on&quot;&gt;&lt;place w:st=&quot;on&quot;&gt;Iran&lt;/place&gt;&lt;/country-region&gt;. Orthosis wearing time is an important factor in orthotic treatment for spine disorders. A reliable and objective System for measuring orthosis wearing time currently is still lacking in Iran. After Developing such a device, our objective was to test the accuracy and validity of the device, Made in Iran which was designed to register spinal orthosis wearing time. The device had a force sensor mounted on a thoracolumbosacral orthosis pad to recorded orthosis wearing time. In an interval of 1 hour 5 &lt;place w:st=&quot;on&quot;&gt;Normal&lt;/place&gt; volunteers tested the device using a CASH orthosis. They donned the orthosis for a few minutes and doffed it meanwhile they recorded the time using a standard chronometer into the &amp;quot;Orthotic Wearing&amp;quot; form. After gaining the data one sample t-test was performed on all orthosis wearing-time intervals as recorded by the system and by the time tables filled by each of the 5 testers using a chronometer. The tests yielded 100 sensor trigger-events that is 50 times of orthotic wear (t=2.21, P=0.032). As indicated by the t-test analysis, the device for registering orthotic wearing time had accurately quantified the orthosis wearing-time intervals during the laboratory climate tests with normal volunteers.&lt;/font&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>مدت زمان استفاده از ارتز</keyword_fa>
	<keyword>Orthosis Wearing Time</keyword>
	<start_page>74</start_page>
	<end_page>90</end_page>
	<web_url>http://ijwph.daneshafarand.org/browse.php?a_code=A-10-29-1&amp;slc_lang=fa&amp;sid=3</web_url>


<author_list>
	<author>
	<first_name> N.</first_name>
	<middle_name></middle_name>
	<last_name>Fallahian</last_name>
	<suffix></suffix>
	<first_name_fa>نادر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فلاحیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>N.Fallahian@gmail.com</email>
	<code>1003194753284600376503</code>
	<orcid>1003194753284600376503</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>F.</first_name>
	<middle_name></middle_name>
	<last_name>Tabatabaei</last_name>
	<suffix></suffix>
	<first_name_fa>سیدفرهاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طباطبایی قمشه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600375023</code>
	<orcid>1003194753284600375023</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Rahgozar </last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رهگذر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600375022</code>
	<orcid>1003194753284600375022</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>R.</first_name>
	<middle_name></middle_name>
	<last_name>VahabKashani </last_name>
	<suffix></suffix>
	<first_name_fa>رضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>وهاب کاشانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600375020</code>
	<orcid>1003194753284600375020</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M.</first_name>
	<middle_name></middle_name>
	<last_name>Bahrami </last_name>
	<suffix></suffix>
	<first_name_fa>محمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بهرامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>1003194753284600375019</code>
	<orcid>1003194753284600375019</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
